Class Fuse_occurrence

Documentation

General Information
Owner 3_Part_structure
Applied Stereotype
Base ClassifierComponent_occurrence
Is Abstractfalse
Derived Classifiers

Attributes

Classifier Name Type Mult. Description
Component_occurrence Id String 1

The id specifies the identifier of the Component.

Component_occurrence Alias_id Alias_identification 0..*

The alias_id specifies additional identifiers for the Component.

Component_occurrence Description String 0..1

The description specifies additional information about the object.

Component_occurrence Localized_description Localized_string 0..*

The description specifies additional information about the object. The Localized_description provides the possibility to define descriptions for different language codes.

Fuse_occurrence Designed_operating_current Numerical_value 0..1

The designed operating current is calculated / specified by the consumers available in the network.

Fuse_occurrence Maximum_operating_current Numerical_value 0..1

The maximum operating current is calculated / specified by the weakest used wires.

Outgoing Relations

Other End This General
Type Role Mult. Mult. Description
Consumers attachedConsumers 0..* 1 icon_1227510668.jpg