Protection_area
Note: There is a newer version of this specification see KBL 2.5.sr1
Schutzzone A Protection_area is a a mechanism to describe the area on a Segment covered by a Wire_protection_occurrence. Some segments of a harness are crossing areas with critical conditions like higher temperatures, higher humidity, etc. To prevent the damage of the cable, protect shields are mounted for that segment. Note: For each Segment covered by a particular Wire_protection_occurrence a separate Protection_area has to be instantiated.
General Information
| Attribute | Value |
|---|---|
| Owner | 5_Topology |
| Applied Stereotype | |
| Base Classifier | |
| Is Abstract | false |
| Derived Classifiers |
Attributes
| Name | Type | Mult. | Description | Owning Classifier |
|---|---|---|---|---|
| Start_location | Double | 1 | The start_location specifies the start position of the Wire_protection_occurrence on the Segment. The value is given in curve parameters running from 0.0 to 1.0. | Protection_area |
| End_location | Double | 1 | The end_location specifies the end position of the Wire_protection_occurrence on the Segment. The value is given in curve parameters running from 0.0 to 1.0. | Protection_area |
| Taping_direction | String | 0..1 | The taping_direction specifies the direction of the taping (left/right) regarding to the Segment direction. | Protection_area |
| Gradient | Value_with_unit | 0..1 | The gradient specifies the gradient of the protection. Note: The gradient is defined in mm. Gradient 15 mms means that the winding screws within a turn 15 mms along the bundle. | Protection_area |
Outgoing Relations
| Type | Role | Mult. | Mult. | Description |
|---|---|---|---|---|
| Processing_instruction | Processing_information | 0..* | 1 | |
| Wire_protection_occurrence | Associated_protection | 1 | 0..* |
Incoming Relations
| Type | Mult. | Role | Mult. | Description |
|---|---|---|---|---|
| Segment | 1 | Protection_area | 0..* |