Protection_area

Note: There is a newer version of this specification see KBL 2.5.sr1

Schutzzone A Protection_area is a a mechanism to describe the area on a Segment covered by a Wire_protection_occurrence. Some segments of a harness are crossing areas with critical conditions like higher temperatures, higher humidity, etc. To prevent the damage of the cable, protect shields are mounted for that segment. Note: For each Segment covered by a particular Wire_protection_occurrence a separate Protection_area has to be instantiated.

General Information

AttributeValue
Owner5_Topology
Applied Stereotype
Base ClassifierChanged_element
Is Abstractfalse
Derived Classifiers

Attributes

NameTypeMult.DescriptionOwning Classifier
Start_locationDouble1

The start_location specifies the start position of the Wire_protection_occurrence on the Segment. The value is given in curve parameters running from 0.0 to 1.0.

Protection_area
Absolute_start_locationNumerical_value0..1

The absolute start location defines the start position of a wire protection with an absolute value. This is an extension to the relative value of the "location" attribute. The absolute value is necessary to prevent unintended changes due to segment length changes or rounding errors.

A creating system is responsible to generate this redundant information in a consistent way. If both values are present, the absolute value is the more binding value.

Protection_area
End_locationDouble1

The end_location specifies the end position of the Wire_protection_occurrence on the Segment. The value is given in curve parameters running from 0.0 to 1.0.

Protection_area
Absolute_end_locationNumerical_value0..1

The absolute end location defines the end position of a wire protection with an absolute value. This is an extension to the relative value of the "location" attribute. The absolute value is necessary to prevent unintended changes due to segment length changes or rounding errors.

A creating system is responsible to generate this redundant information in a consistent way. If both values are present, the absolute value is the more binding value.

Protection_area
Taping_directionString0..1

The taping_direction specifies the direction of the taping (left/right) regarding to the Segment direction.

Protection_area
GradientValue_with_unit0..1

The gradient specifies the gradient of the protection. Note: The gradient is defined in mm. Gradient 15 mms means that the winding screws within a turn 15 mms along the bundle.

Protection_area

Outgoing Relations

TypeRoleMult.Mult.Description
Processing_instructionProcessing_information0..*1
Wire_protection_occurrenceAssociated_protection10..*

Incoming Relations

TypeMult.RoleMult.Description
Segment1Protection_area0..*