General_terminal
Note: There is a newer version of this specification see KBL 2.5.sr1
Kontakt A General_terminal is a device designed to terminate a conductor to be affixed usually to a post, stud, chassis, or other conductor or the like in order to establish electrical connection. Note: A General_terminal describes the active part of the connector, which connects electrical, equal to "contact".
General Information
Attribute | Value |
---|---|
Owner | 2_Parts |
Applied Stereotype | |
Base Classifier | Part |
Is Abstract | false |
Derived Classifiers |
Attributes
Name | Type | Mult. | Description | Owning Classifier |
---|---|---|---|---|
Part_number | String | 1 | The part_number specifies the identifier of the Part. The format of the part number is user defined (company specific). |
Part |
Company_name | String | 1 | The company_name specifies the name of the organizational context in which the Part_number is defined. |
Part |
Alias_id | Alias_identification | 0..* | The alias_id specifies an additional part_number that is used to identify the Part in another organizational context (e.g. company). |
Part |
Version | String | 1 | The version specifies the version identifier of the Part. A version cumulates and consolidates one or more single changes. |
Part |
Abbreviation | String | 1 | The abbreviation specifies a short name for a Part. |
Part |
Description | String | 1 | The description specifies additional information about the Part. |
Part |
Localized_description | Localized_string | 0..* | The description specifies additional information about the object. The Localized_description provides the possibility to define descriptions for different language codes. |
Part |
Predecessor_part_number | String | 0..1 | The predecessor_part_number specifies the part number of the predecessor of the Part. |
Part |
Degree_of_maturity | String | 0..1 | The degree_of_maturity specifies the degree of maturity of a Part. Where applicable the following values shall be used: - ‘draft’ - ‘planning’ - ’equipment order’ - ‘disposition’ |
Part |
Copyright_note | String | 0..1 | The copyright_note specifies copyright information for a Part. |
Part |
Mass_information | Numerical_value | 0..1 | The mass_information specifies the mass of a Part. Example: Valid values for the unit of the Numerical_value specifying the mass are ‘gram’, ‘kilogram’, or also ‘kg/piece’, ‘gram/meter’ |
Part |
Part_number_type | Part_number_type | 0..1 | Defines the type of a Part_number since part numbers are used in the process to identify different characteristics. See the OpenEnumeration Part_number_type. The default value is ‘real part’ the attribute is not defined. |
Part |
Terminal_type | Terminal_type | 0..1 | The terminal_type specifies the type of a General_terminal. Note: There are no values pre-defined. Special values have to be negotiated between exchange partners. Example: ‘pin’, ‘Blade’, ‘male’, ‘female’, ‘grease’, ‘FL - flat contact’, ‘KK - box contact’, ‘SK - ring wire’, ‘RK - ring lug’, ‘KS - lug’, ‘BK - battery clamp’, ‘OL - open line end of frame’, ‘SP - splice’, ‘MK - multiple contact’ |
General_terminal |
Plating_material | String | 0..1 | The plating_material specifies the overlaying of a thin coating of metal on components to improve conductivity, provide for easy soldering or prevent rusting or corrosion. |
General_terminal |
Cross_section_area | Value_range | 0..1 | The cross_section_area specifies the electrical cross section, which can be accommodated by the General_terminal. |
General_terminal |
Outside_diameter | Value_range | 0..1 | The outside_diameter specifies the outer width of the isolation, which can be accommodated by the General_terminal. |
General_terminal |
Incoming Relations
Type | Mult. | Role | Mult. | Description |
---|---|---|---|---|
KBL_container | 1 | General_terminal | 0..* | |
Terminal_occurrence | 1..* | Part | 1 | |
Special_terminal_occurrence | 1..* | Part | 1 |