Protection_area

Note: There is a newer version of this specification see KBL 2.5.sr1

Schutzzone A Protection_area is a a mechanism to describe the area on a Segment covered by a Wire_protection_occurrence. Some segments of a harness are crossing areas with critical conditions like higher temperatures, higher humidity, etc. To prevent the damage of the cable, protect shields are mounted for that segment. Note: For each Segment covered by a particular Wire_protection_occurrence a separate Protection_area has to be instantiated.

General Information

Attribute Value
Owner 5_Topology
Applied Stereotype
Base Classifier Changed_element
Is Abstract false
Derived Classifiers

Attributes

Name Type Mult. Description Owning Classifier
Start_location Double 1

The start_location specifies the start position of the Wire_protection_occurrence on the Segment. The value is given in curve parameters running from 0.0 to 1.0.

Protection_area
Absolute_start_location Numerical_value 0..1

The absolute start location defines the start position of a wire protection with an absolute value. This is an extension to the relative value of the "location" attribute. The absolute value is necessary to prevent unintended changes due to segment length changes or rounding errors.

A creating system is responsible to generate this redundant information in a consistent way. If both values are present, the absolute value is the more binding value.

Protection_area
End_location Double 1

The end_location specifies the end position of the Wire_protection_occurrence on the Segment. The value is given in curve parameters running from 0.0 to 1.0.

Protection_area
Absolute_end_location Numerical_value 0..1

The absolute end location defines the end position of a wire protection with an absolute value. This is an extension to the relative value of the "location" attribute. The absolute value is necessary to prevent unintended changes due to segment length changes or rounding errors.

A creating system is responsible to generate this redundant information in a consistent way. If both values are present, the absolute value is the more binding value.

Protection_area
Taping_direction String 0..1

The taping_direction specifies the direction of the taping (left/right) regarding to the Segment direction.

Protection_area
Gradient Value_with_unit 0..1

The gradient specifies the gradient of the protection. Note: The gradient is defined in mm. Gradient 15 mms means that the winding screws within a turn 15 mms along the bundle.

Protection_area

Outgoing Relations

Type Role Mult. Mult. Description
Protection_area Is_on_top_of 0..* 0..*

Specifies constraints on ordering of Protection_areas. All referenced Protection_areas have to be below (nearer to the center of the Segment) this Protection_area. (see KBLFRM-171, KBLFRM-750)

Processing_instruction Processing_information 0..* 1
Wire_protection_occurrence Associated_protection 1 0..*

Incoming Relations

Type Mult. Role Mult. Description
Protection_area 0..* Is_on_top_of 0..*

Specifies constraints on ordering of Protection_areas. All referenced Protection_areas have to be below (nearer to the center of the Segment) this Protection_area. (see KBLFRM-171, KBLFRM-750)

Segment 1 Protection_area 0..*
Previous