CouplingPoint
Note: There is a newer version of this specification see VEC 2.1.0
A CouplingPoint defines a single coupling. If a coupling takes place, all sub elements are connected. If the coupling is disconnected, all subelements are disconnected.
If a coupling occurs between two connectors, and not just between two terminals, the CouplingPoint references the respective ConnectorHousingRoles.
General Information
Attribute | Value |
---|---|
Owner | coupling |
Applied Stereotype | |
Base Classifier | ConfigurableElement |
Is Abstract | false |
Derived Classifiers |
Attributes
Name | Type | Mult. | Description | Owning Classifier |
---|---|---|---|---|
identification | String | 0..1 | CouplingPoint |
Outgoing Relations
Type | Role | Mult. | Mult. | Description |
---|---|---|---|---|
MatingPoint | matingPoint | 0..* | 1 | Specifies the MatingPoints defined by the MatingSpecification. |
ConnectorHousingRole | firstConnector | 0..1 | 0..* | |
ConnectorHousingRole | secondConnector | 0..1 | 0..* | |
SlotCoupling | slotCoupling | 0..* | 1 |
Incoming Relations
Type | Mult. | Role | Mult. | Description |
---|---|---|---|---|
CouplingSpecification | 1 | 0..* |