BoltTerminalSpecification
Note: There is a newer version of this specification see VEC 2.2.0
Specification for the definition of bolt terminals. These are the counterparts to ring terminals.
General Information
| Attribute | Value |
|---|---|
| Owner | electrical_parts |
| Applied Stereotype | |
| Base Classifier | TerminalSpecification |
| Is Abstract | false |
| Derived Classifiers |
Attributes
| Name | Type | Mult. | Description | Owning Classifier |
|---|---|---|---|---|
| identification | String | 1 | Specifies a unique identification of the specification. The identification is guaranteed to be unique within the document containing the specification. For all VEC-documents a Specification-instance can be trusted to be identical if the DocumentVersion-instance is the same (see DocumentVersion) and the identification of the Specification is the same. | Specification |
| description | AbstractLocalizedString | 0..* | Specifies additional, human readable information about the specification. | Specification |
| specialPartType | String | 0..1 | The specialPartType allows the specification of subclassifications for a PartOrUsageRelatedSpecification (e.g. different types of connector housings). | PartOrUsageRelatedSpecification |
| voltageRange | ValueRange | 0..1 | Specifies the allowed voltage range for the connector housing. | TerminalSpecification |
| sealingType | TerminalSealingType | 0..1 | Defines the SealingType of the Terminal. This type always refers to the sealing of the terminal itself. However, even a terminal which is not sealable can be used in sealed locations with additional measures (e.g. on the slot). | TerminalSpecification |
| connectionALength | NumericalValue | 0..1 | Specifies the length of the terminal between the contact area (terminal reception) and the crimp are (wire reception, see diagram "Terminal Dimensions"). | TerminalSpecification |
| overallLength | NumericalValue | 0..1 | Specifies the overall length the terminal (see diagram "Terminal Dimensions"). | TerminalSpecification |
| boltDiameter | NumericalValue | 0..1 | Specifies the diameter of the bolt in a nominal way. | BoltTerminalSpecification |
| boltHeight | NumericalValue | 0..1 | Specifies the height of the bolt (the height of the part to which ring terminals can be attached). | BoltTerminalSpecification |
| boltNominalSize | TerminalBoltNominalSize | 0..1 | Defines the size (diameter) of the bolt in a nominal way (e.g. "M8"). | BoltTerminalSpecification |
| boltType | TerminalBoltType | 0..1 | Specifies the type of the bolt. | BoltTerminalSpecification |
| torsionProtection | Boolean | 0..1 | Specifies if the bolt provides torsion protected or not. | BoltTerminalSpecification |
| maxTerminalCount | Integer | 0..1 | Defines the maximum number of (ring) terminals that can be attached to this bolt at the same time. | BoltTerminalSpecification |