InsulationCrimpDetail

The InsulationCrimpDetail defines crimp values for a insulation crimp. The selection criteria to which the InsulationCrimpDetail applies are defined by the referenced InsulationSpecification and the ConductorSpecification referenced by the containing CoreCrimpDetail.

General Information

AttributeValue
Ownerelectrical_parts
Applied Stereotype
Base ClassifierCrimpDetail
Is Abstractfalse
Derived Classifiers

Attributes

NameTypeMult.DescriptionOwning Classifier
sizeSize0..1

Defines the expected size of the crimp. The height is measured in direction of the crimp opening. The width is measured in orthogonal to the height and orthogonal to main axis of the terminal (TerminalSpecification.OverallLength).

CrimpDetail
pullOffForceNumericalValue0..1

The minimum force that the completed crimp should withstand when wire is being pulled off the terminal. Above that force, the crimp can be expected to be destroyed at any time.

InsulationCrimpDetail

Outgoing Relations

Other EndThis EndGeneral
RoleTypeMult.Agg.UniqueOrderedMult.Description
appliesToInsulationSpecification1NYN

Incoming Relations

This EndOther EndGeneral
RoleMult.Agg.UniqueOrderedTypeMult.Description
insulationCrimpDetails0..*YYNCoreCrimpDetail1

Defines the different InsulationCrimpDetails that are valid combinations for this CoreCrimpDetail.