ReferenceSurfaceDefinition
Published on Sep 19, 2025
VEC Version 2.2.0
1 min read
A connector housing can define reference surfaces that serve as contact surfaces in a work piece holder. Those reference surfaces normally have defined tolerance limits to support accurate determination of cavity positions for example during the insertion process.
Attribute | Value |
---|
Owner | electrical_parts |
Applied Stereotype | |
Base Classifier | |
Is Abstract | false |
Derived Classifiers | |
Attributes
Name | Type | Mult. | Description | Owning Classifier |
---|
hasSurfaces | Boolean | 1 | Specifies whether the connector has defined references surfaces or not. | ReferenceSurfaceDefinition |
dimensionX | NumericalValue | 0..1 | Specifies the distance and tolerance between the middle axis of the lowest alpha numerical cavity (origin of the connector coordinate system) and the reference surface in direction of the X-axis. | ReferenceSurfaceDefinition |
dimensionY | NumericalValue | 0..1 | Specifies the distance and tolerance between the middle axis of the lowest alpha numerical cavity (origin of the connector coordinate system) and the reference surface in direction of the X-axis. | ReferenceSurfaceDefinition |
Incoming Relations
This End | Other End | General |
---|
Role | Mult. | Agg. | Unique | Ordered | Type | Mult. | Description |
---|
referenceSurfaceDefinition | 0..1 | Y | Y | N | ConnectorHousingSpecification | 1 | Contains the information about reference surfaces of the connector. |